EEG-ECoG recording

From NeuroTychoWiki
Jump to: navigation, search

20110607S2_EEGandECoG_Su_Oosugi+Naoya-Nagasaka+Yasuo-Hasegawa+Naomi_mat_ECoG128-EEG18

Oosugi Naoya

  • Data
    ECoG05_anesthesia.mat and EEG05_anesthesia.mat
    Processing
    The data were processed in Matlab.
    • Band-pass filter
      4th order butter worth filter(Signal Processing Toolbox)
      Regression
      PCA+Linear regression(Statistics Toolbox)
      PCA was used as whitening.
      Model Estimation
      4-fold cross validation test
      It did NOT destroy the structure of time-series.
      Prediction rate
      Correlation coefficient between test data and predicted data
    Result

EEG head map 1 45.png

  • 1. Plotted EEG time points prediction rate via ECoG time points on head map
    EEGs and ECoGs were bandpass-filtered between 1 and 45 Hz. Color bar means prediction rate. Black points means locations of EEG channels(without Cz) but these are not correct because this subject is monkey! This figure shows that all EEG channels can be predicted via ECoG and prediction rate of left EEGs is better than right.

Bp all.png

  • 2. Compared EEG prediction rate via ECoG during time-frequency bands
    EEGs and ECoGs were bandpass-filtered in the time-frequency bands of Theta(between 4 and 7Hz), Alpha(between 8 and 13Hz), low Beta(between 14 and 20Hz), high Beta(between 21 and 30Hz) and Gamma(between 31 and 45Hz). x-axis means time-frequency bands and y-axis means locations of EEG channels. Color bar means prediction rate. This figure shows high frequency components of EEGs are harder to be predicted via ECoGs.

Theta.png

  • 3. Prediction rate of EEGs in the frequency band of Theta via ECoGs in the frequency band of Theta or not
    EEGs in the frequency band of Theta were predicted via ECoGs in the frequency band of Theta and ECoGs without the frequency band of Theta(bandcut-filtered between 4 and 7Hz). x-axis means locations of EEG channels and y-axis means prediction rate. Blue bar means prediction rate of Thete EEGs via Theta ECoGs and red bar means prediction rate of Theta EEGs via EEGs without Theta components. This figure shows the time-frequency band of EEG and ECoG is very similar.

T8 1 45.png

  • 4.ECoG prediction rate via EEG in the time-frequency between 1 and 45Hz
    EEGs and ECoGs were bandpass-filtered between 1 and 45 Hz. Color points means locations of ECoG electrodes and [R = prediction rate * 255, G = 0, B = 0](If prediction rate < 0 then R = 0). This figure shows EEGs include informations of low frequency components of ECoG.

T8 60 100.png

  • 5.ECoG prediction rate via EEG in the time-frequency between 60 and 100Hz
    EEGs and ECoGs were bandpass-filtered between 60 and 100 Hz. Color points means locations of ECoG electrodes and [R = prediction rate * 255, G = 0, B = 0](If prediction rate < 0 then R = 0). This figure shows EEGs do NOT include informations of high frequency components of ECoG.